Alcatel-Lucent 1675 LambdaUnite Installation And System Turn-Up Manual page 65

Multiservice switch (mss)
Table of Contents

Advertisement

Safety
Table 1-1
Circuit pack
OP10/01{80/800G
(KFA9, KFA8 { 159)
OP10/9285XT{8650XT
(KFA210 { KFA482)
OP10D (KFA630) with
OM10/1.5IR1 (OM10G14)
OM10/1.3IOR1 (OM10G7)
OM10/1.5LR1 (OM10G6)
Gigabit-Ethernet circuit pack
GE1/SX4 (KFA13)
GE1/LX4 (KFA532)
Notes:
1.
SM: Single-mode fiber, MM: multi-mode fiber.
2.
It is the class of the circuit pack, not that of the telecommunications system as a whole, that is specified.
3.
The OP10/1.5LR1 circuit packs delivered with 1675 LambdaUnite MSS Releases 1.0 or 2.0 are classified
as Class 3A laser products in accordance with the IEC classification (cf.
(p.
1-16)).
Connector types
All optical circuit packs are equipped with LC-type connectors. It is highly
recommended to use 45° angled boots on all LC connectors.
....................................................................................................................................................................................................................................
365-374-179R10.0
Issue 2, June 2009
Optical circuit pack specifications (continued)
Wavelength
Fiber type
[nm]
(core/cladding
diameter [µm])
1530.72 {
SM (9/125)
1562.23
1554.537
SM (9/125)
...
1607.466
.
.
1550
SM (9/125)
1310
SM (9/125)
1550
SM (9/125)
850
MM (50/125)
1310
SM (50/125)
Alcatel-Lucent - Proprietary
See notice on first page
1
Max. output
Min. optical
power
sensitivity
[mW / dBm]
[dBm]
0.41 / -3.8
-20
0.63 / -2
-13
.
.
1.6 / +2
-14
0.8 / –1
-11
2.5 / +4
-24
0.4 / −4
-17
0.5 / −3
-19
Optical circuit pack specifications
Max.
Laser
overload
class
[dBm]
(IEC / FDA)
-13
1 / I
-3
1 / I
.
.
-1
1 / I
-1
1 / I
-7
1 / I
0
1 / I
-3
1 / I
"Laser product classification"
2