44
Table 12: ES-80-08k40 Configurations
Camera Link Mode Configuration (Controlled by clm command)
Command
Camera Link
Configuration
clm 2
Base
clm 3
Base
clm 15
Med iu m
clm 16
Med iu m
03-032-20070-02
Camera Link Taps
2 Cam era Link taps
2 Cam era Link taps
4 Cam era Link taps
w here:
1 = CCD tap
1+2+3+4
2 = CCD tap
5+6+7+8
3 = CCD tap
9+10+11+12
4 = CCD tap
13+14+15+16
4 Cam era Link taps
w here:
1 = CCD tap
1+2+3+4
2 = CCD tap
5+6+7+8
3 = CCD tap
9+10+11+12
4 = CCD tap
13+14+15+16
Readout Direction (Controlled by
command)
smm
Bit
Depth
smm 0
8
= CL tap 1(1-4096)
CL tap 2(4097-8192)
smm 1
= CL tap 1(8192-4097)
CL tap 2(4096-1)
smm 0
12
= CL tap 1(1-4096)
CL tap 2(4097-8192)
smm 1
= CL tap 1(8192-4097)
CL tap 2(4096-1)
smm 0
8
= CL tap 1(1-2048)
CL tap 2(2049-4096)
CL tap 3(4097-6144)
CL tap 4(6145-8192)
smm 1
= CL tap 1(8192-6145)
CL tap 2(6144-4097)
CL tap 3(4096-2049)
CL tap 4(2048-1)
smm 0
12
= CL tap 1(1-2048)
CL tap 2(2049-4096)
CL tap 3(4097-6144)
CL tap 4(6145-8192)
smm 1
= CL tap 1(8192-6145)
CL tap 2(6144-4097)
CL tap 3(4096-2049)
CL tap 4(2048-1)
Piranha ES-xx User Manual
Pixel Rate
Configuration
(Controlled by sot
command)
sot 40
= 20 MH z
strobe
(m ax line rate 4836
H z)
sot 80
= 40 MH z
strobe
(m ax line rate 9671
H z)
sot 40
= 20 MH z
strobe
(m ax line rate 4836
H z)
sot 80
= 40 MH z
strobe
(m ax line rate 9671
H z)
sot 80
= 20 MH z
strobe
(m ax line rate
9583H z)
sot 160
= 40 MH z
strobe
(m ax line rate
19157H z)
sot 80
= 20 MH z
strobe
(m ax line rate
9583H z)
sot 160
= 40 MH z
strobe
(m ax line rate
19157H z)