Mnemonic
set m irror m od e
set output throughput
set pretrigger
set prnu coeff
set prnu range
set subtract
background
03-032-20070-02
Syntax
Parameters
smm
i
sot
m
spt
i
spc
x i
spr
i i x
ssb
t i
Piranha ES-xx User Manual
Description
Set the cam era's m irror m od e:
0: Pixels read out left to right (1 to 4096
or 8192)
1: Pixels read out right to left (8092 or
4096 to 1)
Refer to 3.4.4 Setting the Pixel Read out
Direction for d etails.
This com m and w orks in conjunction
w ith the clm com m and and d eterm ines
the Cam era Link strobe rate.
40 = 2 taps at 20MH z
80 = 2 taps at 40MH z
80 = 4 taps at 20MH z
160 = 2 taps at 80MH z or 4 taps at
40MH z
320 = 4 taps at 80MH z or 8 taps at
40MH z
640 = 8 taps at 80MH z
Refer to section 3.4.3 Setting the Cam era
Throughput for d etails on using this
com m and . Available settings are
d epend ent on your cam era m od el.
Set the pretrigger to a value from 0 to
16.
Set the PRN U coefficient.
x=pixel num ber w ithin the range 1 to
sensor pixel count.
i= PRN U value w ithin the range 0 to
28671.
Set a range of pixel PRN U coefficients
i=first pixel num ber of the range
i=last pixel num ber of the range
x=coefficient value in a range from 0 to
28671.
Refer to Setting a Range of PRN U
Coefficients on page 65 for d etails.
Subtract the input value from the
output signal.
t = Tap value. 0 for all taps or 1 to
number of CCD taps for ind ivid ual
tap selection.
i = Subtracted value in a range from 0
to 4095.
Refer to Subtracting Backgroun d on
page 61 for d etails.
Teledyne DALSA