Dalsa Piranha ES-80-08k40-00-R User Manual page 43

Enhanced sensitivity cameras
Table of Contents

Advertisement

Piranha ES-xx User Manual
Table 11: ES-80-04k40 Configurations
Camera Link Mode Configuration (Controlled by clm command)
Command
Camera Link
Configuration
clm 15
Med iu m
clm 16
Med iu m
clm 21
Fu ll
Teledyne DALSA
Camera Link Taps
Bit
Depth
4 Cam era Link taps
8
w here:
1 = CCD tap
1 + 2
2 = CCD tap
3 + 4
3 = CCD tap
5 + 6
4 = CCD tap
7 + 8
4 Cam era Link taps
w here:
1 = CCD tap
1 + 2
2 = CCD tap
3 + 4
3 = CCD tap
5 + 6
4 = CCD tap
7 + 8
8 Cam era Link taps
w here:
1 = CCD tap 1
2 = CCD tap 2
3 = CCD tap 3
4 = CCD tap 4
5 = CCD tap 5
6 = CCD tap 6
7 = CCD tap 7
8 = CCD tap 8
Readout Direction (Controlled by
command)
smm
smm 0
= CL tap 1 (1-1024)
CL tap 2 (1025-2048)
CL tap 3 (2049-3072)
CL tap 4 (3073-4096)
smm 1
= CL tap 1 (4096-3073)
CL tap 2 (3072-2049)
CL tap 3 (2048-1025)
CL tap 4 (1024-1)
smm 0
12
= CL tap 1 (1-1024)
CL tap 2 (1025-2048)
CL tap 3 (2049-3072)
CL tap 4 (3073-4096)
smm 1
= CL tap 1 (4096-3073)
CL tap 2 (3072-2049)
CL tap 3 (2048-1025)
CL tap 4 (1024-1)
smm 0
8
= CL tap 1 (1-512)
CL tap 2 (513-1024)
CL tap 3 (1025-1536)
CL tap 4 (1537-2048)
CL tap 5 (2049-2560)
CL tap 6 (2561-3072)
CL tap 7 (3073-3584)
CL tap 8 (3585-4096)
smm 1
= CL tap 1 (4096-3585)
CL tap 2 (3584-3073)
CL tap 3 (3072-2561)
CL tap 4 (2560-2049)
CL tap 5 (2048-1537)
CL tap 6 (1536-1025)
CL tap 7 (1024-513)
CL tap 8 (512-1)
43
Pixel Rate
Configuration
(Controlled by sot
command)
sot 320
= 80 MH z
strobe
(m ax rate 68610 H z)
sot 160
= 40 MH z
strobe
(m ax line rate 37629
H z)
sot 320
= 80 MH z
strobe
(m ax line rate 68610
H z)
sot 160
= 40 MH z
strobe
(m ax line rate 37629
H z)
sot 320
= 40 MH z
strobe
(m ax line rate 68610
H z)
03-032-20070-02