Error Messages
Camera Response
Error 01: Internal error xx>
Error 02: Unrecognized com m and >
Error 03: Incorrect num ber of
param eters>
Error 04: Incorrect param eter value> This response returned for
Error 05: Com m and unavailable in
this m od e>
Error 06: Tim eout>
Error 07: Cam era settings not saved > Ind icates that user settings have been corrupted by
Error 08: Unable to calibrate - tap
outsid e ROI>
Error 09: The cam era's tem perature
exceed s the specified operating
range>
Error 10: FPGA Flash Program Failed FCS failed either because of com m unication error or a
03-032-20070-02
Comment
Where xx is a cod e list below .
Only output d uring pow er up.
Custom er should contact custom er support.
Com m and is not valid .
Too m any or too few param eters.
Alpha received for nu m eric or visa versa
Float w here integer expected
N ot an elem ent of the set of possible valu es.
E.g., Bau d Rate
Ou tsid e the range lim it
E.g. SSF w hen in SEM 3
Com m and not com pleted in tim e. E.g. CCF or CCP in
SEM 3 w hen no external EXSYN C is present.
turning off the pow er w hile executing the WUS
com m and . Must build up new settings from factory
and re-save w ith WUS.
Cannot calibrate a tap that is not part of the end of line
statistics.
Ind icates that the cam era has shut itself d ow n to
prevent d am age from further overheating. (flashing
red )
Shuts d ow n at in ternal tem perature of 75˚C and w ill
not restart until below 65˚C (equivalent to 50˚C at front
plate).
bad file w as sent.