Dalsa Piranha ES-80-08k40-00-R User Manual page 57

Enhanced sensitivity cameras
Table of Contents

Advertisement

Piranha ES-xx User Manual
In the follow ing exam ple, analog gain is set for all taps. The peak valu e of each tap w ithin
the region of interest is calibrated to the specified target valu e. All taps com pletely
ou tsid e the region of interest are calibrated to the average analog gain valu e of the taps
insid e the region of interest.
Figure 22: Calculating Analog Gain for all Taps
Setting Analog Offset
Purpose:
Syntax:
Syntax Elem ents:
Exam ple:
Teledyne DALSA
4095
3040
0
0
W hen calibrating all taps , taps com pletely outs ide the region
of interes t (in this exam ple, taps 1to 4 and 14 to 16) are calibrated to the
average analog gain of taps within the region of interes t. T aps
within the region of interes t calibrate to the target value. Note: S eam s
between taps will be vis ible until you perform P R NU calculation us ing
the ccp com m and.
Sets the analog offset. The analog offset should be set so that it is
at least 3 tim es the rm s noise value at the current gain. The analog
offset is configured for noise at the m axim um specified gain and
as a result you should not need to ad just the analog offset.
sao t i
t
i
sao 3 35
R e gion of Inte re s t
2600
P ix el Num ber
S cenario 3: ccg 1 0 3040
A fte r analog gain c alibration
B efore analog gain c alibration
Tap selection. Use 0 for all taps or 1 to num ber of CCD taps
for ind ivid ual tap selection.
Offset value in a range from 0 to 255DN (12 bit LSB).
V ide o
8192
6400
03-032-20070-02
57