Exposure Modes in Detail
Fram e rate is set by the period of the external trigger pu lses. EXSYN C pu lses faster than
the read ou t tim e are ignored . The falling ed ge of EXSYN C m arks the start of read ou t.
N ote: In TDI m od e the fram e period equ als the line period .
Figure 14: Mode 3 Timing
Mode 3
EXSYNC
Mode 7: Internal Frame Rate, Maximum Exposure Time
In this m od e, the fram e rate is set internally u sing the
exposu re tim e.
N ote: In TDI m od e the fram e period equ als the line period .
Figure 15: Mode 7 Camera Timing
Internal Sync set
with
03-032-20070-02
Frame Period
Readout
Exposure Time
Falling Edge
Ignored During
Readout
Frame Period
Exposure Time
Readout
Command
ssf
ssf
EXSYNC Falling
Edge ignored
during readout
Piranha ES-xx User Manual
Frame Period
Readout
Exposure Time
Falling Edge
Ignored During
Readout
com m and w ith a m axim u m
Frame Period
Exposure Time
Readout
EXSYNC Falling
Edge ignored
during readout