Dalsa Piranha ES-80-08k40-00-R User Manual page 63

Enhanced sensitivity cameras
Table of Contents

Advertisement

Piranha ES-xx User Manual
Setting a Pixel's FPN Coefficient
Purpose:
Syntax
Syntax Elem ents:
N otes:
Exam ple:
Returning FPN Coefficients
Purpose:
Syntax:
Syntax Elem ents:
N otes:
Exam ple:
Setting a Range of FPN Coefficients
Purpose:
Syntax
Syntax Elem ents:
N otes:
Exam ple:
Teledyne DALSA
Sets an ind ivid ual pixel's FPN coefficient.
sfc x i
x
The pixel num ber from 1 to sensor pixel count.
i
Coefficient value in a range from 0-511 (12-bit LSB).
Available in TDI Mod e only.
sfc 10 50
Returns a pixel's FPN coefficient value in DN (12-bit LSB)
gfc i
i
The pixel num ber to read in a range from 1 to sensor pixel
count.
Available in TDI Mod e only.
gfc 10
Sets a range of pixel FPN coefficients.
sfr x x i
x
The first pixel num ber of the range.
x
The last pixel num ber of the range.
i
Coefficient value in a range from 0-2048.
The first pixel of the range m ust be less than the last.
sfr 1 100 80