Dalsa Piranha ES-80-08k40-00-R User Manual page 84

Enhanced sensitivity cameras
Table of Contents

Advertisement

84
Syntax
get spc
get spt
get ssb
get ssf
get ssg
get stg
get sut
get svm
get tdi
get ugr
get vt
get vv
get wfc
get wpc
get wus
03-032-20070-02
Parameters
Description
x
Returns the PRN U coefficient for the specified pixel
num ber.
x=pixel num ber w ithin the range 1 to sensor pixel
count.
Returns the current pretrigger setting.
t
Returns the current background subtract value.
t = Tap value. 0 for all taps or 1 to number of CCD
taps for ind ivid ual tap selection.
Returns the current line/ fram e rate in H z.
t
Returns the current d igital gain setting.
t = tap selection, either 1 to number of CCD taps, or
0 for all taps
Returns the current num ber of CCD integration stages.
Returns the current upper threshold value.
Returns the current vid eo m od e.
0: N orm al vid eo m od e
1: Test pattern
2: Test pattern
3: Test pattern
Returns the cam era's current operatin g m od e.
0: Area Mod e
1: TDI Mod e
Returns the gain reference value
Returns the cam era's internal chip tem perature in d egrees
Celsius.
Returns the cam era's supply voltage.
Returns w hether FPN coefficients have been saved .
0 = N o FPN coefficients saved
1 = Pixel coefficients have been saved
Returns w hether PRN U coefficients have been saved .
0 = N o PRN U coefficients saved
1 = Pixel coefficients have been saved
Returns w hether user settings have been saved .
0 = N o user settings saved
1 = User settings have been saved
Piranha ES-xx User Manual
Teledyne DALSA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents