Sign In
Upload
Manuals
Brands
Dalsa Manuals
Computer Hardware
Everywhereyoulook Xtium2-CXP PX8
Dalsa Everywhereyoulook Xtium2-CXP PX8 Manuals
Manuals and User Guides for Dalsa Everywhereyoulook Xtium2-CXP PX8. We have
1
Dalsa Everywhereyoulook Xtium2-CXP PX8 manual available for free PDF download: User Manual
Dalsa Everywhereyoulook Xtium2-CXP PX8 User Manual (139 pages)
Brand:
Dalsa
| Category:
Computer Hardware
| Size: 4 MB
Table of Contents
Table of Contents
3
Overview
10
Product Part Numbers
10
Table 1: Xtium2-CXP PX8 Board Product Numbers
10
Table 2: Xtium2-CXP PX8 Software Product Numbers
10
Table 3: Xtium2-CXP PX8 Cables & Accessories
10
Xtium2-CXP PX8 Frame Grabber Features
11
User Programmable Configurations
11
Acuplus: Acquisition Control Unit
12
DTE: Intelligent Data Transfer Engine
12
PCI Express X8 Gen3 Interface
12
Advanced Controls Overview
12
Development Software Overview
13
Sapera LT Library
13
Sapera Processing Library
13
About Coaxpress
13
Quick Start Setup & Installation
14
Installing Xtium2-Cxp Px8
18
Nstallation Verview
18
Hardware Installation
18
Nstructions )
18
Multi-Board Sync & I/O Setup
18
Sapera LT Library & Xtium2-CXP PX8 Driver Installation
19
Installation Procedure
19
Xtium2-CXP PX8 Firmware Update
19
Firmware Update: Automatic Mode
20
Firmware Update: Manual Mode
20
Figure 1: Automatic Firmware Update
20
Executing the Firmware Update Program from the Start Menu
21
Figure 2: Manual Firmware Update
21
Figure 3: Start Menu Firmware Update Shortcut
21
Upgrading Sapera or Board Driver
22
Board Driver Upgrade Only
22
Upgrading both Sapera and Board Driver
22
Preserving Board Parameters During Driver Upgrade
23
Figure 4: Device Manager Parameter Setting Differences
23
Preserving Board Parameters During Board Replacement or System Cloning
24
Figure 5: Firmware Update Status
24
Figure 6: same Firmware for All Devices Checkbox
24
Isplaying Tium 2-Cxp Px8 Board Nformation
25
Device Manager - Board Viewer
25
Figure 7: Board Information Via Device Manager
25
Information Field Description
26
Changing Device Settings
29
Device Information Report
30
Figure 8: Device Manager File Menu Save Device Info Command
30
Configuring Sapera
31
Increasing Contiguous Memory for Sapera Resources
31
Host Computer Frame Buffer Memory Limitations
32
Contiguous Memory for Sapera Messaging
32
Camexpert Quick Start
33
Nterfacing Cxp Ccameras with Cam Expert
33
Camexpert Example with a Monochrome Camera
33
Figure 9: Camexpert Program
33
Figure 10: Camexpert Device Tree
34
Camexpert Demonstration and Test Tools
35
Camera Types & Files
35
Overview of Sapera Acquisition Parameter Files (.Ccf or .Cca/.CVI)
35
Saving a Camera File
36
Camera Interfacing Check List
36
Using Camexpert with Xtium2-CXP PX8
37
Basic Timing Category
38
Parameter Descriptions
38
Advanced Control Category
40
Parameter Descriptions
41
External Trigger Category
43
Parameter Descriptions
44
Image Buffer and Roi Category
46
Parameter Descriptions
47
Using the Flat Field Correction Tool
48
Xtium2-CXP PX8 Flat Field Support
48
Loading the Required Camera File
48
Set up Dark and Bright Acquisitions with the Histogram Tool
48
Verify a Dark Acquisition
48
Verify a Bright Acquisition
49
Figure 11: Camexpert Histogram of Dark Image
49
Flat Field Correction Calibration Procedure
50
Figure 12: Camexpert Histogram of Bright Image
50
Figure 13: Camexpert Flat Field Correction Menu Command
50
Flat Field Correction Dialog
51
Using Flat Field Correction
51
Figure 14: Camexpert Flat Field Correction Dialog
51
Using the Bayer Filter Tool
52
Bayer Filter White Balance Calibration Procedure
52
Using the Bayer Filter
52
Sapera Demo Applications
53
Table 4: Demos Workspace Details
53
Figure 15: the Sapera Explorer Application
53
Grab Demo Overview
54
Using the Grab Demo
54
Xtium2-Cxp Px8 Reference
55
Block Diagram
55
Figure 16: Xtium2-CXP PX8 Block Diagram
55
Xtium2-CXP Flow Diagram
56
Figure 17: Xtium2-CXP Flow Diagram
56
Line Trigger Source Selection for Line Scan Applications
57
Table 5: CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE - Parameter Values
57
Haft Ncoder Nterface Iming
58
Figure 18: Encoder Input with Pulse-Drop Counter
58
Figure 19: Using Shaft Encoder Direction Parameter
59
Synchronization Signals for a 10 Line Virtual Frame
60
Can Cameras
60
Synchronization Signals for Fixed Frame Length Acquisition
61
Figure 20: Synchronization Signals for a 10 Line Virtual Frame
61
Figure 21: Line Scan, Fixed Frame, no Trigger
61
Synchronization Signals for Variable Frame Length Acquisition
62
Figure 22: Line Scan, Fixed Frame, Edge Trigger
62
Figure 23: Line Scan, Fixed Frame, Level Trigger (Roll-Over to Next Frame)
62
Figure 24: Line Scan, Variable Frame, Edge Trigger (Active High Determines Frame Length)
62
Figure 25: Line Scan, Fixed Frame, Level Trigger (Roll-Over)
63
Sapera Acquisition Methods
64
Trigger to
65
Rigger to Mage Eliability
65
Supported Events and Transfer Methods
65
Acquisition Module Events
65
Acquisition Device Events
66
Transfer Events
67
Trigger Signal Validity
68
Supported Transfer Cycling Methods
68
Table 6: Buffer States
69
Output Lut Availability
70
Table 7: Output LUT Availability
70
Metadata: Theory of Operation
71
Metadata Data Structure
71
Clearing Metadata Counters
71
Metadata Example
71
Flat Field Correction: Theory of Operation
72
Flat Field Correction Lists
72
Flat Field Correction Sets
72
Xtium2-CXP PX8 Specific Limitations
72
Programming the Sets
73
Xtium2-CXP PX8 Supported Parameters
74
Camera Related Capabilities
74
Camera Related Parameters
74
Table 8: Camera Related Capabilities
74
Table 9: Camera Related Parameters
74
VIC Related Parameters
76
Table 10: VIC Related Parameters
76
ACQ Related Parameters
80
Table 11: Acquisition Related Parameters
80
Transfer Related Capabilities
82
Transfer Related Parameters
82
Table 12: Transfer Related Capabilities
82
Table 13: Transfer Related Parameters
82
General Outputs #1: Related Capabilities (for GIO Module #0)
83
General Outputs #1: Related Parameters (for GIO Module #0)
83
General Inputs #1: Related Capabilities (for GIO Module #1)
83
General Inputs #1: Related Parameters (for GIO Module #1)
83
Table 14: GIO-0 Related Capabilities
83
Table 15: GIO-0 Related Parameters
83
Table 16: GIO-1 Related Capabilities
83
Table 17: GIO-1 Related Parameters
83
Bidirectional General I/Os: Related Capabilities (for GIO Module #2)
84
Bidirectional General I/Os: Related Parameters (for GIO Module #2)
84
Table 18: GIO-1 Related Parameters
84
Table 19: GIO-2 Related Parameters
84
Sapera Servers and Resources
85
Table 20: Xtium2-CXP PX8 - Servers and Resources
85
Technical Specifications
87
Xtium2-CXP PX8 Board Specifications
87
Table 21: Board Specifications
87
Host System Requirements
88
Table 22: Environment Specifications
88
Table 23: Power Specifications
88
Emc Declarations of Conformity
89
FCC Statement of Conformance
89
FCC Class a Product
89
CE Declaration of Conformity
89
Connector and Switch Locations
90
Xtium2-CXP PX8 Board Layout Drawing
90
Connector / LED Description List
90
Table 24: Board Connector List
90
Figure 26: Board Layout
90
Connector and Switch Specifications
91
Xtium2-CXP PX8 End Bracket Detail
91
Figure 27: End Bracket Details
91
Status Leds Functional Descriptions
92
S: Boot-Up/Pcie Status LED
92
L1, L2, L3, L4: Coaxpress Status LED
92
Table 25: S Boot-Up/Pcie Status LED
92
Table 26: Camera CXP Status LED
92
J7: External I/O Signals Connector (Female DH60-27P)
93
Table 27: DH60-27P Connector Signals
93
J8: Internal I/O Signals Connector (40-Pin TST-120-01-G-D)
94
Table 28: 40-Pin TST-120-01-G-D Connector Signals
94
Note 1: General Inputs / External Trigger Inputs Specifications
95
Figure 28: General Inputs Electrical Diagram
95
Table 29: External Trigger Timing Specifications
96
Table 30: Input Switching Points and Propagation Delay
96
Figure 29: External Trigger Input Validation & Delay
96
Block Diagram: Connecting External Drivers to General Inputs
97
Figure 30: External Signals to J7 Connection Diagram
97
External Driver Electrical Requirements
98
Table 31: External Driver Electrical Requirements
98
Figure 31: External Signals to J8 Connection Diagram
98
Note 2: General Outputs /Strobe Output Specifications
99
Figure 32: General Outputs Electrical Diagram
99
Block Diagram: Connecting External Receivers to the General Outputs
100
Figure 33: Output Signals to J7 Connection Diagram
100
External Receiver Electrical Requirements
101
Table 32: External Receiver Electrical Requirements
101
Figure 34: Output Signals to J8 Connection Diagram
101
Note 3: RS-422/TTL Shaft Encoder Input Specifications
102
Figure 35: RS-422 Shaft Encoder Input Electrical Diagram
102
Note 3.1: Interfacing to an RS-422 Driver Output
104
Figure 36: External RS-422 Signals to J7 Connection Diagram
104
Figure 37: External RS-422 Signals to J8 Connection Diagram
105
Note 3.2: Interfacing to a Line Driver (also Called Open Emitter) Output
106
Note 3.3: Interfacing to an Open Collector Output
106
Figure 38: Interfacing to a Line Driver Output
106
Figure 39: Interfacing to an Open Collector Output
106
Note 3.4: Interfacing Directly to a TTL (also Called Push-Pull) Output
107
Note 3.5: Interfacing to a TTL Using a Bias Voltage
107
Figure 40: Interfacing TTL to TTL Shaft Encoder Inputs
107
Figure 41: Interfacing TTL to RS-422 Shaft Encoder Inputs Using a Bias Voltage
107
C1, C2, C3, C4: Coaxpress Connector
108
J9: Multi-Board Sync / Bi-Directional General I/Os
108
Hardware Preparation
108
Configuration Via Sapera Application Programming
108
Configuration Via Sapera Camexpert
109
J10: Power Connector
110
DC Power Details
110
Cables & Accessories
111
Coaxpress Cables
111
DH40-27S Cable to Blunt End (OR-YXCC-27BE2M1, Rev B1)
111
Table 33: Coaxpress Cable Suppliers
111
Figure 42: DH60-27P Cable No. OR-YXCC-27BE2M1 Detail
111
Figure 43: Photo of Cable OR-YXCC-27BE2M1
112
DH40-27S Connector Kit for Custom Wiring
113
Figure 44: OR-YXCC-H270000 Custom Wiring Kit
113
Cable Assemblies for I/O Connector J8
114
External Signals Connector Bracket Assembly
114
External Signals Connector Bracket Drawing
114
External Signals Connector Bracket Pinout
114
Figure 45: DB37 Output Cable
114
Table 34: DB37 Cable Connector Details
115
Board Sync Cable Assembly OR-YXCC-BSYNC40
116
Figure 46: Photo of Cable OR-YXCC-BSYNC40
116
Power Cable Assembly OR-YXCC-PWRY00
117
Figure 47: Photo of Cable Assembly OR-YXCC-PWRY00
117
Coaxpress Interface
118
Coaxpress Overview
118
Appendix A: Silent Installation
119
Silent Mode Installation
119
Creating a Response File
119
Running a Silent Mode Installation
120
Silent Mode Uninstall
120
Creating a Response File
120
Running a Silent Mode Uninstall
120
Nstallation Etup with or Pp Auncher Exe
121
Ilent Ode Nstallation Eturn Ode
121
Ustom River Nstallation Using Install Ini
122
Creating the Install.ini File
122
Run the Installation Using Install.ini
122
Figure 48: Create an Install.ini File
122
Appendix B: Troubleshooting Problems
123
Overview
123
Problem Type Summary
123
First Step: Check the Status LED
123
Possible Installation Problems
123
Possible Functional Problems
124
Troubleshooting Procedures
125
Diagnostic Tool Overview
125
Diagnostic Tool Main Window
125
Figure 49: Diagnostic Tool "Resource in Use
125
Figure 50: Diagnostic Tool Main Window
126
Diagnostic Tool Self-Test Window
127
Camera Input Eye Diagram Monitor
127
Figure 51: Diagnostic Tool Main Window
127
Figure 52: Eye Diagram
127
Diagnostic Tool Live Monitoring Window
128
Checking for PCI Bus Conflicts
128
Figure 53: Diagnostic Tool Live Monitoring Window
128
Figure 54: PCI Diagnostic Program
129
Figure 55: PCI Diagnostic Program - PCI Bus Info
129
Windows Device Manager
130
BSOD (Blue Screen) Following a Board Reset
130
Figure 56: Using Windows Device Manager
130
Sapera and Hardware Windows Drivers
131
Recovering from a Firmware Update Error
131
Driver Information Via the Device Manager Program
131
Table 35: Xtium2-CXP PX8 Device Drivers
131
Information Window
132
Figure 57: Board Firmware Version
132
Sapera Log Viewer
133
On-Board Image Memory Requirements for Acquisitions
133
Symptoms: Camexpert Detects no Boards
134
Troubleshooting Procedure
134
Symptoms: Xtium2-CXP PX8 Does Not Grab
134
Symptoms: Card Grabs Black
134
Symptoms: Card Acquisition Bandwidth Is Less than Expected
135
Symptoms: Pocxp Does Not Power the Camera
135
Figure 58: PCI Diagnostic Tool
135
Over-Current Protection Circuit Is Tripped
136
Figure 59: Camexpert Pocxp Parameter
136
Figure 60: Camexpert Video Status Bar
136
Figure 61: Bad Vs. Good CXP Connectors
137
Revision History
138
Contact Information
139
Echnical Support
139
Advertisement
Advertisement
Related Products
Dalsa Everywhereyoulook Linea Lite GigE
Dalsa Piranha ES-80-08k40-00-R
Dalsa Piranha ES-80-04k40-00-R
Dalsa Piranha ES-82-04k40-00-R
Dalsa Piranha ES-80-08k80-00-R
Teledyne DALSA Piranha ES-82-04k80-00-R
Dalsa Piranha ES-S0
Dalsa ES-S0-12K40 HSLink
Dalsa Everywhereyoulook Xtium2-CL MX4
Dalsa PC2-Comp Express OC-P2EM-COMP0
Dalsa Categories
Digital Camera
Security Camera
Security Sensors
Media Converter
Machine Vision Systems
More Dalsa Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL