6 How to Program the Low Harmonic Drive

6.5.6 Data Readouts 16-**

Par.
Parameter description
No. #
16-0* General Status
16-00 Control Word
16-03 Status Word
16-3* AF Status
16-30 DC Link Voltage
16-34 Heatsink Temp.
16-35 Inverter Thermal
16-36 Inv. Nom. Current
16-37 Inv. Max. Current
16-39 Control Card Temp.
16-40 Logging Buffer Full
16-49 Current Fault Source
16-6* Inputs & Outputs
16-60 Digital Input
16-66 Digital Output [bin]
16-71 Relay Output [bin]
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1
6
16-84 Comm. Option STW
16-85 FC Port CTW 1
16-9* Diagnosis Readouts
16-90 Alarm Word
16-91 Alarm Word 2
16-92 Warning Word
16-93 Warning Word 2
16-94 Ext. Status Word
6.5.7 AF Settings 300-**
NOTE!
Except for par. 300-10, it is not recommended to change the settings in this par. group for the Low Harmonic Drive.
Par.
Parameter description
No. #
300-0* General Settings
300-00 Harmonic Cancellation Mode
300-01 Compensation Priority
300-1* Network Settings
300-10 Active Filter Nominal Voltage
300-2* CT Settings
300-20 CT Primary Rating
300-21 CT Secondary Rating
300-22 CT Nominal Voltage
300-24 CT Sequence
300-25 CT Polarity
300-26 CT Placement
300-29 Start Auto CT Detection
300-3* Compensation
300-30 Compensation Points
300-35 Cos-phi Reference
6-70
Default value
4 set-up
(SR = Size related)
0 N/A
All set-ups
0 N/A
All set-ups
0 V
All set-ups
0 °C
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 °C
All set-ups
[0] No
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
4 set-up
(SR = Size related)
[0] Overall
All set-ups
[0] Harmonics
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[1] 5A
2 set-ups
342 V
2 set-ups
[0] L1, L2, L3
2 set-ups
[0] Normal
2 set-ups
[1] Load Current
2 set-ups
[0] Off
All set-ups
0.0 A
All set-ups
0.500 N/A
All set-ups
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
VLT AQUA Low Harmonic Drive Instruction
FC 302
Change dur-
Conver-
only
ing opera-
sion index
tion
FALSE
0
FALSE
0
FALSE
0
FALSE
100
FALSE
0
FALSE
-2
FALSE
-2
FALSE
100
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FC 302
Change
Conver-
only
during op-
sion index
eration
TRUE
-
TRUE
-
FALSE
0
FALSE
0
FALSE
-
FALSE
0
FALSE
-
FALSE
-
FALSE
-
FALSE
-
TRUE
-1
TRUE
-3
Manual
Type
V2
V2
Uint16
Uint8
Uint8
Uint32
Uint32
Uint8
Uint8
Uint8
Uint16
Int16
Int16
V2
V2
V2
Uint32
Uint32
Uint32
Uint32
Uint32
Type
Uint8
Uint8
Uint32
Uint32
Uint8
Uint32
Uint8
Uint8
Uint8
Uint8
Uint32
Uint16