6 How to Program the Low Harmonic Drive
6.4.10 9-** Profibus
Par.
Parameter description
No. #
9-00
Setpoint
9-07
Actual Value
9-15
PCD Write Configuration
9-16
PCD Read Configuration
9-18
Node Address
9-22
Telegram Selection
9-23
Parameters for Signals
9-27
Parameter Edit
9-28
Process Control
9-44
Fault Message Counter
9-45
Fault Code
9-47
Fault Number
9-52
Fault Situation Counter
9-53
Profibus Warning Word
9-63
Actual Baud Rate
9-64
Device Identification
9-65
Profile Number
9-67
Control Word 1
9-68
Status Word 1
6
9-71
Profibus Save Data Values
9-72
ProfibusDriveReset
9-80
Defined Parameters (1)
9-81
Defined Parameters (2)
9-82
Defined Parameters (3)
9-83
Defined Parameters (4)
9-84
Defined Parameters (5)
9-90
Changed Parameters (1)
9-91
Changed Parameters (2)
9-92
Changed Parameters (3)
9-93
Changed Parameters (4)
9-94
Changed parameters (5)
6.4.11 13-** Smart Logic Controller
Par.
Parameter description
No. #
13-0* SLC Settings
13-00
SL Controller Mode
13-01
Start Event
13-02
Stop Event
13-03
Reset SLC
13-1* Comparators
13-10
Comparator Operand
13-11
Comparator Operator
13-12
Comparator Value
13-2* Timers
13-20
SL Controller Timer
13-4* Logic Rules
13-40
Logic Rule Boolean 1
13-41
Logic Rule Operator 1
13-42
Logic Rule Boolean 2
13-43
Logic Rule Operator 2
13-44
Logic Rule Boolean 3
13-5* States
13-51
SL Controller Event
13-52
SL Controller Action
6-56
Default value
4 set-up
(SR = Size related)
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
126 N/A
1 set-up
[108] PPO 8
1 set-up
0
All set-ups
[1] Enabled
2 set-ups
[1] Enable cyclic master
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[255] No baud rate found
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Off
All set-ups
[0] No action
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
Default value
(SR = Size related)
null
null
null
[0] Do not reset SLC
null
null
ExpressionLimit
ExpressionLimit
null
null
null
null
null
null
null
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
VLT AQUA Low Harmonic Drive Instruction
Change during
Conver-
operation
sion index
TRUE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
FALSE
-
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
4 set-up
Change dur-
Conver-
ing operation
sion index
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
All set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-3
1 set-up
TRUE
-3
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
2 set-ups
TRUE
-
Manual
Type
Uint16
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
V2
Uint8
Uint16
OctStr[2]
V2
V2
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Type
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int32
TimD
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8