6 How to Program the Low Harmonic Drive
6.4.3 1-** Load / Motor
Par.
Parameter description
No. #
1-0* General Settings
1-00
Configuration Mode
1-03
Torque Characteristics
1-06
Clockwise Direction
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-28
Motor Rotation Check
1-29
Automatic Motor Adaptation (AMA)
1-3* Addl. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-39
Motor Poles
6
1-5* Load-Indep. Setting
1-50
Motor Magnetization at Zero Speed
1-51
Min Speed Normal Magnetizing [RPM]
1-52
Min Speed Normal Magnetizing [Hz]
1-58
Flystart Test Pulses Current
1-59
Flystart Test Pulses Frequency
1-6* Load-Depend. Settg.
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-7* Start Adjustments
1-71
Start Delay
1-73
Flying Start
1-77
Compressor Start Max Speed [RPM]
1-78
Compressor Start Max Speed [Hz]
1-79
Compressor Start Max Time to Trip
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-86
Trip Speed Low [RPM]
1-87
Trip Speed Low [Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Source
6-50
Default value
(SR = Size related)
null
[3] Auto Energy Optim. VT
[0] Normal
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] OFF
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
30 %
200 %
100 %
100 %
0 %
ExpressionLimit
100 %
5 ms
0.0 s
[0] Disabled
ExpressionLimit
ExpressionLimit
5.0 s
[0] Coast
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[4] ETR trip 1
[0] No
[0] None
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
VLT AQUA Low Harmonic Drive Instruction
4 set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
-
All set-ups
FALSE
1
All set-ups
FALSE
-2
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
-2
All set-ups
FALSE
67
All set-ups
FALSE
-
All set-ups
FALSE
-
All set-ups
FALSE
-4
All set-ups
FALSE
-4
All set-ups
FALSE
-4
All set-ups
FALSE
-3
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
-3
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
Manual
Type
Uint8
Uint8
Uint8
Uint32
Uint32
Uint16
Uint16
Uint32
Uint16
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Int16
Int16
Int16
Uint16
Uint16
Uint8
Uint16
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint8
Need help?
Do you have a question about the VLT AQUA and is the answer not in the manual?