6.9.4

WLAN

6.9.4.1

Basic (Access Point)

Safety levels
To make the network secure, authentication and encryption are used. On this page, you
specify the security settings.
Note
WLAN mode IEEE 802.11 n
With devices operated in WLAN mode IEEE8002.11n, only WPA2 (WPA2-PSK and WPA2
Radius) encryption is possible.
iPCF, iPCF-HT or iPCF-MC mode activated
If iPCF, iPCF-HT or iPCF-MC mode is enabled, only "iPCF authentication" with or without
the AES encryption is supported with security context 1.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
Configuring with Web Based Management
6.9 "Security" menu
369