Configuring with Web Based Management
6.5 "System" menu
SCALANCE W700 and STEP 7
The Ethernet interface can be configured in STEP 7 if the following requirements are met:
● STEP 7 V13 Update 3 with HSP0107 or
● STEP7 version 5.5.4 with GSDML version 2.31
The diagnostics functions can also be used. The WLAN interface cannot be configured with
STEP 7.
PROFINET for client devices
If a client is to be used as a PROFINET device, the MAC address of the client must be
specified as follows (MAC Mode):
● Own
In the network beyond the device, only IP communication and no PROFINET is possible.
● Layer 2 Tunnel
The client and the devices downstream from it can be used as PROFINET devices.
Note
If "Automatic" or "Manual" is configured as the MAC mode for a client, this device cannot
be used as a PROFINET device.
6.5.18

EtherNet/IP

EtherNet/IP
On this page, you configure the mode of EtherNet/IP.
256
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13