● max. Tx Power
Specify the transmit power of the device. It may be necessary to reduce the transmit
power when using antennas to avoid exceeding the maximum legal transmit power.
Reducing the transmit power effectively reduces cell size
Note
The maximum possible transmit power varies depending on the channel and data rate.
For more detailed information on transmit power, refer to the documentation
"Characteristics radio interface".
Note
If both interfaces of access points with two WLAN interfaces are operated in the same
frequency range, this may cause wireless interference on one or both interfaces at a
transmit power higher than 15 dBm.
● Tx power check
Indicates whether the settings that have been made will violate the permitted transmit
power restrictions of the selected country. The following parameters influence this
calculation:
max. Tx Power, Antenna Gain, Additional Attenuation.
The following displays can appear:
– Allowed
– Not Allowed (Some Channels)
– Not Allowed (All Channels)
– Controlled automatically by iREF
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
The channels can be used with the current settings.
Among the channels, there are some on which the current transmit power exceeds the
maximum permitted transmit power.
No permitted operation is possible. The transmit power is too high.
The transmit power is set by the "iREF" function.