Configuring with Web Based Management
6.5 "System" menu
The table contains the following columns:
● Select
Select the check box in a row to be deleted.
● SMTP Server Address
Shows the IP address, the FQDN (Fully Qualified Domain Name) or the host name of the
SMTP server.
● Receiver Email Address
Enter the e-mail address to which the device sends an e-mail if a fault occurs.
Procedure
1. Enable the "SMTP Client" option.
2. Enter the IP address, the FQDN or the host name of the SMTP server in the "SMTP
Server Address" input box.
3. Click the "Create" button. A new entry is generated in the table.
4. In the "Receiver Email Address" input box, enter the e-mail address to which the device
sends an e-mail if a fault occurs.
5. Click the "Set Values" button.
Note
Depending on the properties and configuration of the SMTP server, it may be necessary
to adapt the "Sender E-Mail Address" input box for the e-mails. Check with the
administrator of the SMTP server.
216
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13