6. Change to one of the following menu items to call up the result of the measurement:
– System > Load&Save > HTTP
– System > Load&Save > TFTP
7. The ZIP file contains a CSV file with the results of the measurement..
Measurement results
CSV file
The CSV file contains information on the configuration of the device and detailed information
on all individual measurements and is divided into two areas. The first area contains the
configured settings:
● System Name
The system name of the access point
● Device IP
The IP address of the device
● Device MAC
The MAC address of the device
● Recording Interval
The interval between acquisition of two measured values
The second area is a table. The table contains the following for each measured value:
● Sample
The consecutive number of the measurement
● Timestamp
The time stamp
● The following columns show all frequencies of the selected frequency band. The cells are
only filled for the frequencies for which a value was measured. The measured values
show the signal strength in dBm.
SCALANCE W780/W740 to IEEE 802.11n Web Based Management
Configuration Manual, 08/2018, C79000-G8976-C267-13
Click the "Save" button in the "WLANSpectrumAnalyzer" table row to save the file
"wlan_spectrum_analyzer_SCALANCE_W700.zip" in the file system of the connected
PC.
If necessary, change the file name "wlan_spectrum_analyzer_SCALANCE_W700.zip"
in the "WLANSpectrumAnalyzer" table row. In the table row
"WLANSpectrumAnalyzer", select the "Save file" entry from the drop-down list of the
last column and click the "Save Values" button.
Configuring with Web Based Management
6.6 "Interfaces" menu