II 3058-4
MAKING THE PLUMBING CONNECTIONS
Warning
All plumbing must comply with local and national codes.
CONNECTING THE WATER SUPPLY
1. Connect the input water to the WATER SUPPLY INLET.
Check that:
•
the customer installed a 50 micron WATER FILTER in the input water line. The
FILTER is required.
•
the water pressure is 173 - 448 kPa (25 - 65 psi). If the water pressure is too
high, have the customer install a PRESSURE REGULATOR to prevent the
WASH WATER SOLENOID from malfunctioning.
•
the water temperature is 4.5 - 27°C (40 - 80°F). The water must be a minimum
of 6.7°C (12°F) below the developer temperature set point to provide the
correct developer temperature control. If the water is too cold, the customer
must install a MIXING VALVE.
VACUUM BREAKER
THERMOMETER
HOSE SERVICE
to PROCESSOR
KODAK AG Stuttgart
CHECK VALVE
SHUT-OFF VALVES
Hot and Cold
Water Supply
figure 4-6
4-5
INSTALLATION INSTRUCTIONS
8/1998