INSTALLATION INSTRUCTIONS
LINE VOLTAGES
!
Caution
For all services a GROUND WIRE (N = Neutral) must be provided.
SYSTEM
NOTE
MAINS
(V)
1
200
1
220
1
230
1
240
2
200
2
127/220
3
127/220
4
220/380
4
230/400
4
240/415
2
120/208
3
120/208
NOTE
DESCRIPTION
1
L1, N, / L1, L2 used in this configuration
2
L1, L2, L3 used in this configuration
3
L1, L2 used in this configuration
4
L1, L2, L3 and N used in this configuration
8/1998
FREQUENC
PHASES
Y(Hz)
50 / 60
1 / 2
50 / 60
1 / 2
50 / 60
1 / 2
50 / 60
1 / 2
50 / 60
3
50 / 60
3
50 / 60
3
50 / 60
3
50 / 60
3
50 / 60
3
60
3
60
3
CURREN
SERVICE
T(A)
WIRES
24
2 / 3
24
2 / 3
24
2 / 3
24
2 / 3
19
3
19
4
24
3
11
4
11
4
11
4
19
4
24
3
5-4
Mains Circuit Breaker
A/Phase
A/Phase
Europe
US
32
30
32
30
32
30
32
30
32
20
32
20
32
30
16
20
16
20
16
20
32
20
32
30
KODAK AG Stuttgart
II 3058-4
POLES
2
2
2
2
3
4
3
4
4
4
4
3