STArT-UP

Warning
risk of injury due to incorrect operation.
Improper operation may result in injuries as well as damage to the device and its environment.
Before start-up, ensure that the operating personnel are familiar with and completely understand the
contents of the operating instructions.
Observe safety instructions and information on intended use.
Only adequately trained technicians may start up the device.
12.1

Starting up via manual override

The manual override is ideal for starting up the device and system. The manual override operates without
the device being connected to the power supply and enables manual switching of the valves.
The manual overrides are marked differently depending on the circuit function (CF) of the valves:
CF C, CF Z, CF H (with CF H only 1 manual override):
Marking
Impact of the switched manual override
12
Supply duct 1 connected to working port 2
14
Supply duct 1 connected to working port 4
CF D:
Marking
Impact of the switched manual override
10 (12)
Connection from supply duct 1 to working port 2 interrupted
10 (14)
Connection from supply duct 1 to working port 4 interrupted
Fig. 15:
Manual override of valves
The manual override provides both spring-return and latching action as standard.
Spring return:
If the slide mechanism is moved to an initial resistance, the manual override returns to the unswitched state
once it is released.
Latching:
If the resistance is exceeded, the manual override remains in the switched state after being released. Man-
ually push the slide mechanism back over the locking point to reset the manual override to the unswitched
state.
32
Manual override
not switched
english
Type 8653
Start-up
Manual override
switched