Start-Up; Safety Instructions; Start-Up Process - Burkert 2380 Operating Instructions Manual

Bellow control valve with compact or element actuator
Table of Contents

Advertisement

9.

START-UP

9.1.

Safety instructions

WARNING!
Risk of injury from improper operation!
Improper operation may result in injuries as well as damage
to the device and the surrounding area.
▶ Before start-up, ensure that the operating personnel are
familiar with and have completely understood the contents
of the operating instructions.
▶ Observe the safety instructions and intended use.
▶ Only adequately trained personnel may start up the device/
the system.
9.2.

Start-up process

Before start-up, pneumatic, fluidic and electrical connections
must be established.
Switch on pilot pressure and supply voltage, keep the
process media switched off!
Remove the transparent cap of the controller to gain access
to the DIP switches or operating keys. Observe the special
instructions for potentially explosive areas.
Run the function X.TUNE for an automatic adjustment of
the positioner - see respective operating instructions for the
Type 869x used.
16
english
Type 2380
Start-up
For Type 8692/93: select the input signal (INPUT).
If necessary, specify additional controller settings (via DIP
switches/menu/USB adapter) - see respective operating ins-
tructions.
NOTE!
CAUTION with using the function SET.FACTORY
(reset to factory settings)!
This function does not only reset the settings implemented
by the user, but also all possibly preconfigured customer-
specific settings (referring to devices with additional label
„Customized Settings")
Switch on process media and activate set point.
If necessary, adjust the controller settings.
Tighten transparent cap of the controller again.
The device is now ready for operation.