PROBLEMS
When the main SW is
turned ON, the
machine is not
activated.
Billboard fluorescent
lamp does not glow.
Sounds are emitted
and the lamps are lit,
but the screen is
black.
Sound is not emitted.
CAUSE
The power is not ON.
Incorrect power
source/voltage.
The Circuit Protector of the
AC Unit functioned due to
momentary overcurrent.
The fuse of the fuse holder
was blown out due to
momentary overcurrent.
Faulty connection of
connectors
Fluorescent lamp and glow
lamp need replacement.
Faulty connections for the
visual signal connector or
the monitor power
connector.
Broken monitor.
Sound volume adjustment
is not correct.
Faulty connections for
various connectors.
Malfunctioning board,
amplifier and speaker.
Speaker settings are
incorrect.
COUNTERMEASURES
Firmly insert the plug into the outlet.
Make sure that the power supply/voltage
are correct.
After eliminating the cause of overload,
have the Circuit Protector of the AC Unit
restored.
After eliminating the cause of overload,
replace the specified rating fuse.
Join connectors securely between cabinet
and billboard.
Replace the fluorescent lamp and the glow
lamp.
Check the connections for the monitor and
game board connectors.
Contact the company from whom the unit
was purchased.
Adjust the switch unit's sound adjustment
volume.
Check the connections for the game board,
amp, speakers and volume connectors.
Perform output test and check.
Check the AUDIO OUTPUT setting on the
game setting screen.