8) Remove the nuts that fasten the VR bracket, then remove volume from VR bracket and replace.
9) The wire connected to the volume is used as is. Take away the thermal contraction tube with
nippers or cutter, melt the soldered areas with a soldering iron and remove wire from the volume.
10) Cover the soldered areas with thermal contraction tube. In place of the thermal contraction tube
that was cut away, pass each wire through new thermal contraction tube.
11) Solder the wire to the new volume. Check the wiring diagram to be sure there are no errors in
wiring.
12) Cover the soldered areas with thermal contraction tube. Heat the thermal contraction tube with an
industrial drier so that the tube adheres to soldered areas.
13) Attach the gear and VR bracket to volume.
14) After passing the wire, attach the volume. While your hand is removed from the lever, align gear
mesh so that the D cut surface of the volume shaft is level, facing directly upward, then fasten with
2 screws.
15) Manipulate the lever to check that the gear rotates smoothly.
16) Connect the connector and fasten wire with 2 cord clamps.
17) Attach the throttle cover lower. Be careful that the wire does not get caught anywhere.
18) Turn on the power. Note that initialization takes place.
19) Establish volume settings on the game test mode calibration screen. Simply changing the settings
on calibration screen will not be effective. Terminate the test mode. Note that initialization takes
place when test mode has been terminated.