With the computer disconnected, the periodic predictive data is also buffered in the CSI
2600's internal RAM. The amount of time it will take to fill up the CSI 2600's internal RAM
depends on how periodic predictive data storage settings are configured in the database.
This data will also begin to FIFO when the memory buffer is full.
Data extraction from the CSI 2600
If the computer is reconnected while the CSI 2600 is in DAT recorder mode, any buffered
periodic predictive data that has not been deleted by the FIFO process will automatically
be transferred from internal memory to the database. Transient data will only be written to
the database if a transient alarm event has occurred and the associated data has not been
deleted by the FIFO process. Each transient channel can transfer a configurable amount of
data (up to 30 minutes before and after) when a predefined transient alarm event has
occurred.
When the computer is reconnected, portions of recorded data can be extracted on
demand with AMS Machinery Manager Vibration Analysis. Field-based processing of
multiplexed predictive data continues as usual while Vibration Analysis extracts data.
CAUTION!
If the computer is not connected, data may be lost or overwritten.
3.7

Store data on a NAS hard drive

The default streaming location is the internal hard drive. However, an external NAS drive
can be used as an alternative transient streaming location. The CSI 2600 supports NAS
drives up to 250 GB in size. You can use a NAS hard drive as the primary drive for transient
storage or as a failover drive.
Prerequisites
Connect the NAS drive to the same port that is used to connect to the computer. The NAS
drive must be capable of continuous write speeds of >20 MB/s, 100 Base-T minimum, and
rated for a 100% duty cycle.
Procedure
1.
2.
MHM-97453, Rev 1
In the AMS Machinery Manager Online Configuration tree structure, click one of the
units to display the Unit Properties dialog.
Configure values in the External Network Folder Specifications field.