Archive Management - Emerson Machinery Health Expert CSI 2600 User Manual

Table of Contents

Advertisement

Figure 6-3:
Table 6-2:
Transient Archive Status fields
Field
Message
Component
(variable)
Archive Name
(variable)
Archive Status
Pending
Archiving
Complete
Archive Type
Predicate + parameters
Manual
Percent
00.00%–100.00%
Complete
6.5

Archive management

Archives are stored in folders in C:\RBMnet\RBMsuite\CustData\.
Computers have a finite amount of video display memory that may limit the amount of
graphic data viewed in an archive. To achieve efficient CSI 2600 system operation, an
analyst should regularly review extracted archives and keep only those of interest or only
the portions of interest in each archive. An analyst can extract smaller archives from large
ones using the program Vibration Analysis. To extract and view large amounts of
information from the CSI 2600, an analyst should sequentially extract individual archives of
1 - 2 hours of measurements.
MHM-97453, Rev 1
Online Watch—Transient Archive Status
Description
Displays the machine component associated with the transient archive
group.
Displays the name of the archive that was specified in Online
Configuration.
Range 1500_2985 indicates that the collection predicate is TRUE for
speeds between 1500 and 2985 RPM.
The number in _0__ is reserved to ensure the filename is always unique.
05-30-2007 indicates the date the archive was created, in mm-dd-yyy
format.
10.17.07 indicates the time the archive was created, in hh.mm.ss format.
The system is waiting for post-trigger data to be collected, before
sending that data to the database.
The system is sending a complete set of measurements to the online
server.
All measurements have been sent to the online server.
The archive was initiated by a predicate.
The archive was initiated on-demand by a user.
Displays progress while the system sends measurements to the online
server.
Data collection and analysis
69