Time Waveform Analysis - Emerson Machinery Health Expert CSI 2600 User Manual

Table of Contents

Advertisement

Table C-2:
Input
Type
ACCEL
VEL
DISP
C.3

Time Waveform analysis

Time Waveform analysis includes:
MHM-97453, Rev 1
Spectral units conversion
Input Unit
V / 32.2 ft/s
V / 32.2 ft/s
V / 32.2 ft/s
V / 32.2 ft/s
V / 32.2 ft/s
V / 32.2 ft/s
V / 9.81 m/s
V / 9.81 m/s
V / 9.81 m/s
V / 9.81 m/s
V / 9.81 m/s
V / 9.81 m/s
V / i/s
V / i/s
V / i/s
V / i/s
V / i/s
V / mm/s
V / mm/s
V / mm/s
V / mm/s
V / mm/s
V / mil
V / mil
V / mil
V / micron
V / micron
V / micron
Variance
True Peak
Waveform pk-pk
(continued)
HW Int.
SW Int.
no
no
no
single
no
double
yes
no
yes
single
yes
no
no
no
no
single
no
double
yes
no
yes
single
yes
no
no
yes
no
yes
yes
yes
no
yes
yes
no
no
single
no
no
yes
no
no
no
yes
no
no
no
no
no
no
no
no
no
no
no
no
Data types
SW Diff.
Disp. Unit
no
g
no
in./s
no
mil
no
i/s
no
mil
single
g
no
g
no
mm/s
no
micron
no
mm/s
no
micron
single
g
no
i/s
no
mil
no
mil
single
g
single
i/s
no
mm/s
no
micron
no
micron
single
g
single
mm/s
no
mil
single
i/s
double
g
no
micron
single
mm/s
double
g
89

Advertisement

Table of Contents
loading

Table of Contents