Data collection and analysis
6.6

Create archives manually

There are three major differences between manually created archives and automatically
created archives:
Procedure
1.
2.
3.
Postrequisites
Observe the progress of manual archives in the Transient Archive Status tab.
6.7

Disable archive predicates

An analyst can disable the creation of automatic archives during startup or when the
machine is being cycled and multiple archives are not desired.
Procedure
1.
2.
The predicate State on the Transient Status tab reads Disabled.
To re-enable the archive, right-click on the archive predicate and select Enable Archive
Predicate.
Example: Archive creation
When an archive predicate changes from DISABLED to TRUE, no archive is created.
Consider the following sequence:
1.
2.
70
Manual archives only include information already in the CSI 2600. Automatically-
generated archives can include information which is received after the transient
collection predicate = TRUE.
Manual archives do not automatically have a date-time stamp appended to them.
Ensure that unique names are assigned.
Manual archives may have more than one hour of measurements in them.
Automatically generated archives have a maximum of 60 minutes of
measurements.
In Online Watch, select a component that has transient signals.
Right-click and select Start Transient Archive.
Define the manual archive characteristics.
In the Transient Status tab, right-click on the archive predicate and select Disable
Archive Predicate.
A caution window appears.
Click Okay to confirm disabling.
Archive predicate is false.
Archive predicate is disabled prior to machinery start-up.