Replacing Power Supply - Horizon Fitness APC-61 Manual

Table of Contents

Advertisement

4-19 Replacing Power Supply

Control P.C.B
Noise Filter
Power Supply
Power Supply
PW-24
PW-05
1. Remove the cover of control box.
2. Disconnect all the connectors connected
with control P.C.B. Let cables connected
with terminal board TAN-1 remain.
3. Remove 6 screws fixing control board.
Rotate control board in the direction of the
arrow around terminal board TAN-1.
Power supplies under the control board can
be seen.
4. The right power supply is PW-24 for 24V,
the left is PW-05 for 5V. Replace power
supply.
Though size is different from former ones,
replacement is possible equally.
5. Fix with the opposite order.
4-26
PW-05(DC5V)
PW-24(DC24V)
AC
100V
Input
Ourput
5
4
3
2
1
[Power Supply]