1-6 Calibration of Home Position
1. Set the cutting length to 100.0mm.
- This is the temporary value for comparing the
set value with the actual cut length.
2. Cut some sheets.
- Do not align the sheets on the side guide. Align the
sheets only on the backgauge properly, and cut.
3. Measure the dimension of cut sheets.
- Measure the dimension of the sheets by one
decimal place. 100.6mm is given for an ex-
ample here.
4. Obtain the correction value.
- Correction value is a half of the difference
between the set value and the actual cut length.
- The actual cut length is 100.6mm. Therefore,
the correction value is 0.3mm.
5. Enter a new home position. (Fig.2)
- Show the Backgauge Calibration screen.
(Fig.1, Fig2)
- Add or subtract the correction value which was
calculated in step 4 to or from the current home
position value, and enter the new home position
value. (When the actual cut length is larger than
the set value, substract the correction value.)
- In the case of the example, enter the value which
is subtracted by 0.3 and press the
The backgauge will move to the new home
position.
6. Check.
- Follow the steps 1 through 3 and check that the
set value matches the actual cut length.
7. Rewrite the home position sheet.
- The home position sheet is attached to the
bottom of the control panel box shown in Fig.3.
Rewrite the new home position on it.
button.
Fig.1 "Maintenance" Screen
504007
1_6_1A
1-10
Fig.2 "Backgauge Calibration" Screen
The home position
sheet is attached to
the bottom of the
control panel box.
Fig.3 Location of the Home Position Sheet
504007
1_6_1B
504007
1_6_1C