3-9 Release of Locked Knife

Cause for knife locking
Screw
Washer
Knife
Clamp is at right back of the knife holder.
When knife is fixed with screw without washer
by replacement, the tip of the screw hits on the
clamp. Especially,the left most screw disap-
pears behind the bridge as the knife lifts, the
problem is difficult to find.
For S/N 103001 or above, the screw is
changed so that washer does not come out
from screw. For the machines before, we
recommend you to replace the screw with a
new set of the washer M013192-10 and screw
M013397-00.
To check whether knife is locking
Knife Holder
Clamp
Hydraulic Section
If either of LED in the head of electromagnetic
valve is on when both power and hydraulic
system are turned on, knife is locked.
[Head of Electromagnetic Valve]
Clamp Valve
Knife Valve
[Electromagnetic Valve]
LED
3-10
To release knife (When washer is not set in
the left screw)
Upper Limit Position Sensor
Detection Part
[View from the front side of the machine]
1. Remove front and rear covers of this ma-
chine.
2. Turn the power switch on and put a piece of
steel with tape on the sensitive area of upper
limit position sensor.
- LED on sensor should be on.
- LED of electromagnetic valve turns off.
The machine determines knife holder is at
the upper limit position and stops operation
to lift the knife.
Lamp