Horizon Fitness APC-61 Manual page 23

Table of Contents

Advertisement

2-1
blinks on the Display (Backgauge Does Not Operate) Part 2
Phase of power is lacking.
Even if one of the three-phases AC power
results in open phase, motor does not operate
and blinks on the display.
Control Box
1
2
3
4
5
6
Check input voltage which comes to every
section of this terminal board between R-S, S-
T, and T-R.
When there is no voltage even at one point,
original power is in open phase.
There is problem in control board.
Cement resistance is damaged
When switching the motion of the backgauge
T
(forwards or backwards), short circuit exists
S
R
momentarily and this cement resistance can be
damaged. In this case, replace P.C.B.
LEDs from No.1 to No.6 do not turn on.
When LEDs from No.1 to NO.6 showing
operation of knife, clamp, and backgauge turn
on normally, input signals are OK. If there is
no problem in output motor, SSR may has a
problem. Replace P.C.B.
Backgauge belt is cut.
Control
Box
Varistor
1
2
3
4
5
6
When belt is cut or overturned, power is not
transmitted and screw shaft does not drive.
SSR
LED
Therefore, no pulse rises from encoder.
Cement Resistance
Replace belt with a new one.
As for high speed belt for S/N 103001 or
above, a new wider belt is used which is hard
to overturn. To attach this wider belt to a
previous machine, gauge base and motor base
also must be replaced.
(In case of order, please notice it.)
2-3
Low Speed Belt
High Speed Belt
Motor Blacket
High Speed Motor

Hide quick links:

Advertisement

Table of Contents
loading