2-8 Backgauge Does Not come Forward (But goes backward)

Limit switch remains ÒONÓ.
SW2
Limit switch 1
SW3
Limit switch 2
(When pressure support
plate is used.)
Limit switch 1 or 2 shows normally ÒClosed
(=NC)Ó. When backgauge moves forwards
and activates limit switch, it shows ÒOpenÓ
and stops backgaugeÕs forward motion. If the
actuator of limit switch is on or connector is
disconnected, the control board determines the
detection circuit is ÒOpenÓ and backgauge
can not operate forwards. (Backgauge can go
backwards.)
Check of limit switch: See Ò7-5 Control
Board, Connector LayoutÓ.
CON3
Control Box
When there is continuity between 16 and 15 of
CON3, there is no problem with SW2. When
there is continuity between 16 and 13, there is
no problem with SW3.
2-17
There is problem with high speed motor.
Power is supplied to the high speed motor.
Coil of high speed motor is burnt out.
High speed belt is cut.
There is problem with control board.
As for these 4 symptoms, follow the descrip-
tion in Ò2-7 Backgauge Does Not Operate.Ó