settemptrig

settemptrig
To set the internal case temperature alarm trigger level, use the settemptrig command.
Syntax Description
trigger
Defaults
30° C
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The internal case temperature trigger is measured in degrees Celcius. The system accepts a minimum
value of 0.5°C and a maximum value of 50°C. If a value entered falls outside of this acceptable range,
the command will be ignored and have no effect.
Examples
The following example shows how to set the internal case temperature alarm trigger level.
edfa > settemptrig 29.00
Related Commands
Command
resetmeantrig
settempmean
temp
tempmean
temptrig
Cisco ONS 15501 User Guide
4-44
settemptrig trigger
Modification
This command was introduced.
Description
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the internal case temperature alarm mean level.
Displays the internal case temperature level.
Displays the internal case temperature alarm mean level.
Displays the internal case temperature alarm trigger level.
Specifies the desired internal case temperature alarm trigger level.
Chapter 4