Outsigpwrtrig - Cisco ONS 15501 User Manual

Table of Contents

Advertisement

outsigpwrtrig

outsigpwrtrig
To display the output signal alarm trigger level, use the outsigpwrtrig command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The value for output signal alarm trigger level is displayed in dBm.
Examples
The following example shows how to display the output signal alarm trigger level.
edfa > outsigpwrtrig
20.00 (dBm)
Related Commands
Command
outsigpwr
outsigpwrmean
resetmeantrig
setoutsigpwrmean
setoutsigpwrtrig
Cisco ONS 15501 User Guide
4-28
outsigpwrtrig
Modification
This command was introduced.
Description
Displays the calculated output signal power.
Displays the output signal alarm mean level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the output signal alarm mean level.
Sets the output signal alarm trigger level.
Chapter 4
Command Reference
78-14134-01, Release 1.0

Advertisement

Table of Contents
loading

Table of Contents