setinpwrmean

setinpwrmean
To set the optical input alarm mean level, use the setinpwrmean command.
Syntax Description
mean
Defaults
-20.00 dBm
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The optical input alarm mean is measured in dBm. The system accepts a minimum value of -40 dBm and
a maximum value of 0 dBm. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to set the optical input alarm mean level.
edfa > setinpwrmean -28.00
Related Commands
Command
inpwr
inpwrmean
inpwrtrig
resetmeantrig
setinpwrtrig
Cisco ONS 15501 User Guide
4-38
setinpwrmean mean
Modification
This command was introduced.
Description
Displays the measured optical input power.
Displays the optical input alarm mean level.
Displays the optical input alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the optical input alarm trigger level.
Specifies the desired optical input alarm mean level.