setgainmean

setgainmean
To modify the signal gain and alarm mean, use the setgainmean command.
Syntax Description
mean
Defaults
17.5 dB
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The signal gain and alarm mean is measured in dB. The system accepts a minimum value of 7 dB and a
maximum value of 17.5 dB. If a value entered falls outside of this acceptable range, the command will
be ignored and have no effect.
Examples
The following example shows how to modify the signal gain and alarm mean.
edfa > setgainmean 17.00
Related Commands
Command
gain
gainmean
gaintrig
resetmeantrig
setgaintrig
Cisco ONS 15501 User Guide
4-36
setgainmean mean
Modification
This command was introduced.
Description
Displays the measured optical signal gain.
Displays the configured signal gain and alarm mean level.
Displays the gain alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the gain alarm trigger level.