inpwr

To display the measured optical input power, use the inpwr command.
Syntax Description
This command has no other arguments or keywords.
Defaults
None
Command Types
Does not change configuration
Command Modes
User password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The value for optical input power is displayed in dBm.
Examples
The following example shows how to display the optical input power.
edfa > inpwr
-46.03 (dBm)
Related Commands
Command
inpwrmean
inpwrtrig
resetmeantrig
setinpwrmean
setinpwrtrig
78-14134-01, Release 1.0
inpwr
Modification
This command was introduced.
Description
Displays the optical input alarm mean level.
Displays the optical input alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the optical input alarm mean level.
Sets the optical input alarm trigger level.