Grounding The Chassis; Connecting The Power - Cisco ONS 15501 User Manual

Table of Contents

Advertisement

Chapter 2
Installing the Cisco ONS 15501
The protective cover for the DC power terminals should be installed at all times when the equipment
Caution
is energized, except for any necessary maintenance or troubleshooting.
Warning
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.

Grounding the Chassis

To connect the provided grounding lug to the tapped frame grounding holes and connect the
customer-supplied grounding wire to the DC power terminal connectors, follow these steps:
Step 1
Verify that the primary and user-optional redundant external DC power circuits are disconnected at the
source.
Remove the cover from the DC power terminal connectors. Identify the two tapped frame grounding
Step 2
holes at the upper right side of the Cisco ONS 15501 front panel. (See
Remove the two screws provided for securing the ground lug to the Cisco ONS 15501.
Step 3
Step 4
Connect the 8 AWG grounding wire to the grounding lug. The other end of the wire should be suitably
grounded.
Step 5
Install the grounding lug on the Cisco ONS 15501, using the two provided screws and washers.
Test for proper frame ground using the ohmmeter section of a digital voltmeter. Place one prod on the
Step 6
Cisco ONS 15501 and the other on the frame grounding bus to which the grounding lug and grounding
wire is connected. Observe for a zero-resistance ground.
There is an alternate grounding point on the chassis, located on the left side of the rear panel.
Note

Connecting the Power

To connect the power wiring to the DC power terminal connectors, follow these steps:
Cut and strip the customer-supplied 8 AWG primary and redundant power supply wires, if necessary.
Step 1
Identify the -48 VDC wire and power return wire for the primary and redundant circuit.
Install the primary DC power wiring to the right-hand barrier strip. (See
Step 2
is the -48 V connection. The right-hand screw, marked "RET," is the ground connection.
Install the redundant DC power wiring to the left-hand barrier strip. (See
Step 3
screw is the -48 V connection. The right-hand screw, marked "RET," is the ground connection.
Replace the power connector cover.
Step 4
Step 5
Apply power to the primary and redundant DC circuits.
78-14134-01, Release 1.0
2 2 F e b r u a r y 2 0 0 2
DC Power Connection
Figure
2-3.)
Figure
2-3.) The left-hand screw
Figure
2-3.) The left-hand
Cisco ONS 15501 User Guide
2-5