Chapter 4
Command Reference

setinpwrtrig

To set the optical input alarm trigger level, use the setinpwrtrig command.
Syntax Description
trigger
Defaults
10.00 dBm
Command Types
Changes configuration
Command Modes
Master password protected
Command History
Release
EDFA 1.0
Usage Guidelines
The optical input alarm trigger is measured in dB. The system accepts a minimum value of 1 dB and a
maximum value of 20 dB. If a value entered falls outside of this acceptable range, the command will be
ignored and have no effect.
Examples
The following example shows how to set the optical input alarm trigger level.
edfa > setinpwrtrig 2.00
Related Commands
Command
inpwr
inpwrmean
inpwrtrig
resetmeantrig
setinpwrmean
78-14134-01, Release 1.0
setinpwrtrig trigger
Modification
This command was introduced.
Description
Displays the measured optical input power.
Displays the optical input alarm mean level.
Displays the optical input alarm trigger level.
Resets the signal gain and alarm mean level, gain alarm trigger level, optical
input alarm mean level, optical input alarm trigger level, output signal alarm
mean level, output signal alarm trigger level, internal case temperature
alarm mean level, and internal case temperature alarm trigger level to the
manufacturer's default settings.
Sets the optical input alarm mean level.
Specifies the desired optical input alarm trigger level.
setinpwrtrig
Cisco ONS 15501 User Guide
4-39