EtherNet/IP Tag/File to Modbus Configuration Page
EtherNet/IP Tag/File To Modbus Configuration Page (Continued)
Address (Base 1)
(Default = 1)
Length (Regs/Coils)
(Default = 1)
Save
Delete
Delete All
Add Default
Configuration
Clone Line
Sort By
(IP Address)
(Default = Disabled)
Sort By
(Write Device ID)
(Default = Disabled)
74 - Chapter 7. Data Mapping Menus
Enter the Modbus address in Base 1 format. (The address of the tables starts at
1, instead of 0 for Base 0).
Enter only the lower 16 bits of the address (1-65536).
Enter the number of registers or coils to be read.
When this button is clicked:
The settings are verified.
Any changes are saved.
The Data Mapping process is immediately reconfigured and begins
performing the configured operations.
Enable the line or lines that you want to delete and click the Save button.
Enable the Delete All option and click the Save button to remove all entries.
Adds a default entry to the end of the list. The entry will not become active
until it is saved by clicking Save.
Adds a new configuration entry to the end of the list that is identical to the
entered line number. The entry will not become active until it is saved by
clicking Save.
Note: No action is taken if the entered line number is invalid.
Reorders the list based on the EtherNet/IP PLC IP address when Save is
selected.
Sort By
(Write Device ID)
Will reorder the list based on the Write Device ID when Save is selected.
Reorders the list based on the Write Device ID when Save is selected.
DeviceMaster EIP-MOD User Guide: 2000664 Rev. A