7.8  Installing Adjustable Hardstops

7.8 Installing Adjustable Hardstops

We offer an adjustable hardstop kit for Joint 1 and Joint 2 on the eCobra robots. These are user-
installed options that can be used to limit the work envelope of the robot. The part number for
the kit is 02592-000.

Joint 1 Adjustable Hardstops

The Joint 1 Adjustable Hardstops consist of two black rubber stop cylinders, and the required
screws to install them. There are two locations for the hardstops on each side of the robot, Pos-
ition 1 and Position 2. See the following figure.
Item
1
2
Installation Procedure
1. Remove the plug from desired threaded hole, Position 1 or 2, on each side of the robot.
2. Install the adjustable hardstop into the threaded hole using an 8 mm hex wrench.
Tighten to a torque of 5.1 N·m (45 in-lbf).
3. Repeat the process on the other side of the robot.
142
1
Figure 7-16. Joint 1 Adjustable Hardstops
Table 7-18. Joint 1 Adjustable Hardstop Description
Location for Position 1
Joint 1 Adjustable Hardstop Installed in Position 2
Description
eCobra User's Guide
2
14402-000 Rev. F