5.2  Status Panel Fault Codes
Status
LED
Code
Message
ES
*E-STOP detected
by robot*
F1
*E-STOP detected
by robot*
FM
None
FW
*1394 com-
munications
timeout*
#
h#
*Robot over-
heated*
#
H#
*Motor over-
heating* Mtr #
76
V+
V+
Error
Error
Code
-643
-643
N/A
-927
-606
-1016
eCobra User's Guide
Explanation
detected an encoder
fault.
An E-STOP condition has
been detected by the
robot.
The End-Of-Arm Break-
away Sensor has tripped
(open circuit). Reporting
of this error can be
enabled / disabled via
ACE.
Firmware version mis-
match.
The IEEE 1394 com-
munications system has
failed to initialize or has
lost communications
with the SmartCon-
troller EX.
The temperature sensor
on the embedded pro-
cessor board has
reached its temperature
limit. It may be neces-
sary to slow the motion
or insert pauses to
reduce overall heating.
The motor encoder tem-
perature sensor indic-
ates an
overtemperature.
User Action
product. Please ref-
erence individual
robot manuals for
appropriate actions.
This is a normal
response to many E-
STOP conditions.
Remove the source
of the ESTOP and re-
enable high power.
Re-close the break-
away circuit and re-
enable high power.
Contact your local
Omron support.
This will occur nor-
mally if the
SmartController EX
is powered down sep-
arately from the
robot systems. If it
occurs unex-
pectedly, check the
connections and
integrity of the 1394
cabling.
Check for excessive
ambient tem-
perature, inad-
equate ventilation,
and proper function
of any cooling fans.
Reduce the speed,
acceleration and/or
deceleration of the
robot motions, or
introduce delays in
the application cycle
to give the motor an
opportunity to cool.