NOTE: The eCobra robot system is intended to be installed as a piece of equip-
ment in a permanently-installed system.
Facility overvoltages Protection
The user must protect the robot from excessive overvoltages and voltage spikes. If the country
of installation requires a CE-certified installation, or compliance with
information may be helpful:
Category II overvoltages (i.e., line spikes not directly due to lightning strikes) are not exceeded.
Transient overvoltages at the point of connection to the power source shall be controlled not to
exceed overvoltages Category II, i.e., not higher than the impulse voltage corresponding to the
rated voltage for the basic insulation. The user-supplied equipment or transient suppressor
shall be capable of absorbing the energy in the transient.
14402-000 Rev. F
Table 4-11. Typical Robot Power Consumption
Move
No load—Adept cycle
5.5 kg—Adept cycle
5.5 kg—all joints move
No load—Adept cycle
5.5 kg—Adept cycle
5.5 kg—all joints move
WARNING: ELECTROCUTION RISK
eCobra robot systems require an isolating transformer for connection to mains
systems that are asymmetrical or use an isolated (impedant) neutral. Many
parts of Europe use an impedant neutral.
WARNING: ELECTROCUTION RISK
AC power installation must be performed by a skilled and instructed person—
refer to the Robot Safety Guide. During installation fail-safe lockout measures
must be used to prevent, unauthorized third parties from turning on power.
This is mandated by Clause 5.2.4 of the ISO 10218-1.
Failure to use appropriate power (less than or more than the rated voltage
range of 200-240 VAC) can lead to malfunction or failures of the robot or haz-
ardous situations.
1131-2 requires that the installation must ensure that
IEC
eCobra User's Guide
Average
Power (W)
b
344
b
494
880
b
377
b
531
794
Chapter 4: System Installation
RMS Current
Peak Power
(A)
(W)
1.56
1559
2.25
2061
4.00
2667
1.71
1406
2.41
1955
3.61
2110
 1131-2, the following