5. Highlight the current values for joint 2, and replace them with the new values. See the
following table for recommended softstop values.
J2 Hardstop Position 1
J2 Hardstop Position 2
J2 Hardstop Position 3
Note: J2 Hardstops can be installed in a number of positions, depending
on how the robot workcell needs to be configured. The positions are
spaced 30° apart.
6. Reboot eV+:
Controller > Control > Reboot eV+
The new joint limits will be in effect when the system reboot is done.
14402-000 Rev. F
Table 7-21. Joint 2 Ranges for Adjustable Hardstops
NOTE: This can also be accomplished by momentarily removing 24 VDC
power from the controller.
eCobra User's Guide
Chapter 7: Optional Equipment Installation
Hardstop Value
±
81°
±
51°
±
21°
Recommended
Joint Limit Softstop
Lower limit: – 80°
Upper limit: + 80°
Lower limit: – 50°
Upper limit: + 50°
Lower limit: – 20°
Upper limit: + 20°