Err N°
Failure
328
Err MB1*
Brake sequence error 1
329
Err MB2*
Brake sequence error 2
330
Err MB3*
Brake sequence error 3
331
Err MB4*
Brake sequence error 4
332
Err MB5*
Brake sequence error 5
333
Err MB6*
Brake sequence error 6
334
Err MB7*
Brake sequence error 7
335
Err FIN
Heatsink overheat
336
Err OSD*
Speed deviation excess
337
Err ECT*
Encoder signal loss
338
Err E.1*
Option alarm (connector1)
339
Err E.2*
Option alarm (connector2)
340
Err E.3*
Option alarm (connector3)
341
Err ILF*
Input phase failure
342
Err PTC
PTC thermistor operation
343
Err PE2
Parameter storage error
344
Err CDO*
Output Current detection
345
Err IOH
Inrush overheat
346
Err SER*
Communication error
347
Err AIE*
Analog input error
348
Err USB*
USB communication error
349
Err OS*
Overspeed
350
Err OD*
Position error
351
Err EP*
Encoder phase error
352
Err E.11*
Opposite rotation deceleration
353
Err E.13
Internal circuit error
*: This option or function is not used. If you have this error anyway do the following:
1) Reload the Frequency Inverter Parameters.
2) If the fault is persistent, replace the Frequency Inverter.
68
Failure Name
Failure Name:
Sequence errors during use of the brake function.
See detailed explanation below.
Too much speed deviation during vector control
Problem with the encoder signal
Occurs if there is a contact fault of the connector between
the Frequency Inverter and the communication device or if the
communication device is fitted to connector 1 or 2 or if the
switch on the plug-in device is not on its default setting.
1 phase of the 3-phase input was lost for more than 1 second.
Correct the 3-phase power supply.
Over-temperature of motor PTC (switch AU/PTC must be on PTC)
1) Check if motor cooling fan (if present) functions normally
2) Check for contact faults in the wiring (see electrical scheme)
Problem with parameter storage (EEPROM failure). If the fault is
persistent, replace the Frequency Inverter.
Current exceeded the output current detection level.
Resistor in-rush current limit-circuit overheated.
1) Do not switch the Frequency Inverter on an off quickly.
2) Wait some time (15 min) and try again.
3) If the fault is persistent, replace the Frequency Inverter.
Communication problem on the RS485 terminal-connector.
Overcurrent or overvoltage on input terminal 2/4.
USB communication check-time interval has elapsed.
Speed exceeded the limit during encoder feedback control.
Too much difference between the position command and the
position feedback during position control.
Rotation command is different from the actual motor rotation direction.
Rotation direction of the speed command is different from the
estimated speed, causing overload.
Problem with an internal circuit; replace the Frequency Inverter.