Maytag MXS20 Programming Manual page 53

Front-loading multi-load opl commercial washer
Hide thumbs Also See for MXS20:
Table of Contents

Advertisement

DIAGNOSTIC PROGRAM
The purpose of the Diagnostic Program is to test the washer
functions one by one.
HOW TO GET INTO THE DIAGNOSTIC MENU
n
1. Select Cycle is displayed.
Enter the Setup Mode. (See page 5.)
The Main Menu is now available.
Press ARROW DOWN to select the Service Menu.
Select the Diagnostic Program Menu at the Service Menu.
TEST SEQUENCE
 Display test and door lock test
 Sensor test
 Motor test
 Test of outputs for external liquid detergent pumps
 Water fill, heating and drain test
 BASIC Diagnostic Wash program
Test
Info
Black display followed
1
by a Text display.
***
None
3
Motor Reverse
4
Motor Stop
5
Motor Forward
6
Motor Distribute
7
Motor Low spin
8
Motor High spin
9
Motor Stop
15
Detergents 1..8
20
Inlet 1
21
Drain 1
22
Inlet 2
23
Drain 1 (2)*
24
Inlet 3
25
Drain 1
26
Inlet 4
27
Drain 1
28
Inlet 5
29
Drain 1
30
Inlet 6
31
Drain 1
32
Inlet 17
33
Drain 1
34
Inlet 18
35
Drain 1
50
Tumble
Unload
NOTE: The second drain valve will be opened if the second drain valve has been selected in the Configuration Menu.
No number 2 is displayed at the sensor test as this takes only a fraction of a second.
REMARK: If ++ ++ is displayed at the motor test sequence, then you can Advance (press START) the test Sequence.
Explanation
Door lock test
(locks and unlocks the door 5 times)
Display test
Sensor test
(all washer sensors are tested)
Wash Speed
(inverse direction high spin)
Standstill motor
Wash Speed
(same direction high spin)
Distribution speed
(same direction high spin)
Low spin speed
(same direction high spin)
High spin speed
Free run or controlled deceleration
The external liquid detergent pumps get activated one by one
The washer takes water at inlet 1
The water is drained at drain valve 1
The washer takes water at inlet 2 until the safety level for heating is reached
Heating activated (only if Wait temp = on)
The water is drained at drain valve 1
The washer takes water at inlet 3
The water is drained at drain valve 1
The washer takes water at inlet 4
The water is drained at drain valve 1
The washer takes water at inlet 5
The water is drained at drain valve 1
The washer takes water at inlet 6
The water is drained at drain valve 1
The washer takes water at inlet 7
The water is drained at drain valve 1
The washer takes water at inlet 8
The water is drained at drain valve 1
The tumble sequence
End of the Diagnostic Cycle
Service Menu
Service Menu
Diagnostic Prog ...
Diagnostic Prog ...
Select Diagnostic Program
n
Diagnostic Cycle
Diagnostic Cycle
Start Cycle
Start Cycle
Exit
Exit
Press START if you want to start
n
Diagnostic Program.
• Select diagnos
• Select diagnos
• Press START
• Press START
No
No
53