Maytag MXS20 Programming Manual page 25

Front-loading multi-load opl commercial washer
Hide thumbs Also See for MXS20:
Table of Contents

Advertisement

The Prewash Sequence
Prewash
Wash
Menu Item
Temperature
Inlet
Level
RPM
Detergents Menu...
Supply 1, ..., 8
On Time
Off Time
Time
Signal
Cool Down
Rinse
Description
The water temperature.
The suggested Inlet Valves are related to the temperature and the Soap
Box to be used.
If you insert Inlet Valves other than those suggested, problems
can occur at the water fill process.
The suggested water level depends on the Machine Type.
The suggested RPM depends on the Machine Type.
Time selection for external liquid soap supplies. You can program
up to 4 supplies at the same time; attempting to program more than 4
supplies will generate an error message. Only 4 non-zero supplies per
step are accepted.(Liquid soap supplies must be switched on at the
Configuration Menu.)
The wash action, motor On Time.
Gentle wash action: 3 seconds
(The suggested default values can be adjusted in the Initialization Menu)
The wash action, motor Off Time.
Gentle wash action: 12 seconds
(The suggested default values can be adjusted in the Initialization Menu)
The Prewash Sequence Time.
(for 0 minutes the Prewash sequence will be skipped (programmable in
steps of 0.5 minutes)
When a signal is programmed, a pause will be introduced at the end
of the Wash Step. This allows the operator to add soap for the next step.
A buzzer signal warns the operator that the cycle has been interrupted.
Final Rinse
Soak
Spray
No Wash
Default
Limits
104°F
33.8–113°F
(40°C)
(1–45°C)
11–15
11–18
Normal
See Table A-3
Low
See Table A-5
0 sec
0–99 sec
12 sec
1–99 sec
3 sec
1–99 sec
4 min
0–99.5 min
No
No/Yes
25

Hide quick links:

Advertisement

Table of Contents
loading