CODE
MESSAGE
E80
SoapTimeOut
E81
No Reheat
E82
No Refill
E83
Power Interruption
RTC Reset Bat
E85
Weigh No Comm
E100
Weigh Low
E101
E102
Weigh High
E103
Weigh Balance
E104
Weigh Overload
E105
Weigh Airbags
E300–
MITS ERR
E353
E500–
MEMORY ERR
E525
E550
TRACEABILITY
WRITE
E551
TRACEABILITY
FULL
USB ERRORS
E560–
E563
E600–
SOFTW. ERR
E628
50
Fault Code Overview (continued)
FAILURE
Incorrect signal for liquid
detergent dispensing
Heating failure
Refill failure
No successful wash cycle
termination
Real time clock, no battery
or battery low power
Communication fault
weighing system
Washer weight too low
Washer weight too high
Weight not balanced over
4 load cells
Weight on individual load cell
exceeds maximum
No functional air pressure
system
Specific Mitsubishi inverter
alarm
Memory error
Internal memory error data
for traceability
Internal traceability memory
is full
Errors in communication
with USB flash disk
Software error
FAULT OCCURRENCE
Whole cycle
Wash step (traceability only)
Wash step (traceability only)
Abnormal cycle termination
(traceability only)
End cycle (traceability only)
(models with weighing
system only)
(models with weighing
system only)
(models with weighing
system only)
(models with weighing
system only)
(models with weighing
system only)
(models with weighing
system only)
Whole cycle
Any time
Traceability function,
whole cycle
Traceability function,
whole cycle
Only in advanced menu
data export/import
Any time
ACTION
Full Stop + Tumble
Full Stop + Tumble
Full Stop + Request for Continue
Re-enter wash cycle selections
For information only
Full Stop + Tumble
Do not start
Do not start
Do not start
Full Stop + Tumble
Do not start
Full Stop + Safety Time
Full Stop + Safety Time
For information only
For information only
For information only
Full Stop + Safety Time

Hide quick links: