Maytag MXS20 Programming Manual page 29

Front-loading multi-load opl commercial washer
Hide thumbs Also See for MXS20:
Table of Contents

Advertisement

The Final Rinse Sequence
Prewash
Wash
n Only for top dispenser washers.
n No temperature can be programmed because a Final Rinse is only possible with cold water.
Menu Item
Inlet
Level
RPM
Detergents Menu...
Supply 1, ..., 8
On Time
Off Time
Time
Signal
Cool Down
Rinse
Description
3 Inlets can be programmed.
The suggested Inlet Valves are related to the temperature and
the Soap Box to be used.
IMPORTANT: If you insert Inlet Valves other than those
suggested, problems can occur at the water fill process.
The suggested water level depends on the Machine Type.
The suggested RPM depends on the Machine Type.
Time selection for external liquid soap supplies.
You can program up to 4 supplies at the same time. If you have
programmed more than 4 supplies an error message will be
generated.
Reset the time of the supplies back to 0. Only 4 non-zero times
values can be programmed.
– Liquid soap supplies must be switched on in the
Configuration Menu.
The wash action, motor On Time.
Gentle wash action: 3 sec.
(The suggested default values can be adjusted in the
Initialization Menu)
The wash action, motor Off Time.
Gentle wash action: 12 sec.
(The suggested default values can be adjusted in the
Initialization Menu)
The Final Rinse Sequence Time.
(for 0 minutes the Final Rinse sequence will be skipped)
(programmable in steps of 0.5 minutes)
When a signal is programmed, a pause will be introduced at the
end of the Wash Step. This allows the operator to add soap for
the next step. A buzzer signal warns the operator that the cycle
has been interrupted.
Final Rinse
Soak
Spray
No Wash
Default
Limits
14–17
1, 2, 3, 4, 7
(3 inlets)
Normal
See Table A-3
High
See Table A-5
0 sec
0–99 sec
12 sec
1–99 sec
3 sec
0–99 sec
2 min
0–99.5 min
No
No/Yes
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents